Research

Measurement of Oil Film Thickness Distribution between Slipper and Swash Plate in Swash Plate Axial Piston Pumps [Tanaka Lab]

A swash plate axial piston pump is a hydraulic pump that supplies hydraulic oil to a hydraulic motor or cylinder. This pump has sliding parts where metal parts rub against each other. In this research, the oil film thickness distribution between the slipper and swash plate under severe sliding conditions is measured using a fluorescent method to optimize the design of the sliding parts.

Test bench for measurement of oil film thickness distribution between slipper/swash plate1)

Oil film thickness distribution between slipper/swash plate1)

Source: 1) Journal of Japanese Society of Tribologists, Vol.69, No.1 (2024) p.32-42.